S5 · 24.7 m² single-level accommodation
S5 Space Capsule House
A 24.7 m² single-level guest unit with sleeping, seating and bathroom zones.
- Floor area
- 24.7 m²
- Occupancy
- 2–4 people
- Power
- 10 kW
- Approx. weight
- 5 t (5,000 kg)
S5 accommodation
S5 Guest-Room Layout
S5 combines sleeping, seating and bathroom zones within a 7.5 × 3.3 m footprint, planned for two to four people.

Sleeping, Seating & Bathroom
The layout example places the bathroom beside the entrance, with sleeping and seating zones along the glazed side.
- Occupancy: two to four people in the base schedule.
- Enclosure: galvanised steel frame, polyurethane insulation, aluminium-alloy exterior panels and Low-E insulating glazing.
- Fit-out: bathroom equipment, split-system air conditioning, lighting, curtains and room controls.
Customise dimensions and fit-out for your project. Final specifications and included items follow the agreed quotation.
Specifications
S5 Dimensions & Capacity
Standard dimensions and equipment are shown below. Layout, finishes and equipment changes can affect size, weight and price.
| Parameter | Base configuration |
|---|---|
| Model | S5 Space Capsule House |
| External dimensions (L × W × H) | 7,500 × 3,300 × 3,200 mm (7.5 × 3.3 × 3.2 m) |
| Nominal floor area | 24.7 m² |
| Occupancy | 2–4 people |
| Electrical power | 10 kW |
| Approximate total weight | 5 t (5,000 kg) |
Dimensions are external. Use your final shipping size, unit weight and equipment loads to plan transport and site connections.
Structure and envelope
Frame, Insulation & Glazing
The base envelope combines a galvanised steel frame with aluminium-alloy exterior panels, polyurethane insulation and glazed openings.
| Component | Base configuration |
|---|---|
| Main frame | Galvanised steel-frame structure |
| Exterior panels | Aluminium-alloy panels |
| Exterior coating | Fluorocarbon paint finish |
| Insulation | Polyurethane insulation layer |
| Curtain-wall glazing | Low-E tempered insulating glazing, 6 + 15A + 6 configuration |
| Openable windows | Laminated tempered glazing, 6 + 1.52 + 6 configuration |
| Entrance door | Custom stainless-steel entrance door |
| Entrance lock | Outdoor waterproof smart door lock for hospitality use |
| Equipment compartment | Compartment for air-conditioning and water-heating equipment |
| Equipment-compartment door | Custom aluminium-alloy door |
| Perimeter lighting | Surrounding ambient light strip |
| Top lighting | Surrounding ambient light strip |
Tell us your exterior finish, door and window arrangement, and structural requirements.
Interior finishes
Bedroom & Bathroom Finishes
The standard interior includes panel finishes, SPC flooring, lighting, a motorised curtain track and bathroom finishes.
| Component | Base configuration |
|---|---|
| Bedroom ceiling | Aluminium-alloy ceiling panels |
| Bedroom wall panels | Carbon-crystal decorative panels |
| Bedroom flooring | 6 mm SPC click-lock flooring |
| Bedroom ambient lighting | Surrounding ambient light strips |
| Bedroom general lighting | Downlights |
| Curtain track | Motorised curtain track |
| Bathroom ceiling | Bamboo-wood fibre panels |
| Bathroom wall panels | Carbon-crystal decorative panels |
| Bathroom flooring | Slip-resistant ceramic tiles |
| Bathroom privacy door | One-way frosted tempered-glass door |
Bathroom equipment
Bathroom Fittings & Hot Water
Standard bathroom equipment includes sanitary fixtures, water heating, lighting and ventilation.
| Component | Base configuration |
|---|---|
| Hot-water equipment and shower | Electric water heater and shower fittings |
| Vanity and basin | Custom sintered-stone washbasin and vanity, mirror, cabinet and floor drain |
| Toilet | Toilet fixture |
| Lighting and ventilation | Bathroom lighting and ventilation |
| Accessories | Towel rack |
Select your water-heater capacity and fittings, and confirm water-supply and drainage connections.
Electrical and services
Electrical & Equipment
Tell us the destination, supply voltage, frequency, socket standard and required equipment.
| Component | Base configuration |
|---|---|
| Base wiring | 1.5 / 2.5 / 4 / 10 mm² electrical cables and Category 6 network cable; final cable specification follows destination and equipment requirements |
| Cable conduit | Insulating PVC conduit |
| Water supply and drainage | Pressure-resistant water-supply and drainage pipework |
| Air conditioning | 2 HP-class split-system heating and cooling air conditioner in the base schedule |
| Sockets | Destination-specific sockets; three-hole and five-hole formats are base examples |
| Switches | Switch panels configured for the required destination standard |
The 2 HP class describes the listed air-conditioner size, not an electrical-input or cooling-capacity value. Final equipment and site power requirements follow the agreed schedule.
Room controls
Lighting & Room Controls
Room controls manage lighting, curtains and guest-room power.
| Function | Base configuration |
|---|---|
| Key-card power control | Insert card to enable power; remove card to disconnect power |
| Scene controls | Multi-scene function panel |
| Lighting controls | Intelligent lighting control |
| Curtain controls | Intelligent curtain control |
| Voice controls | Intelligent voice-control system |
Configuration choices
Plan Your S5 Configuration
Choose your layout, exterior finish, interior fittings and equipment before production.
- Layout and occupancy: confirm the intended use, room arrangement and required occupancy.
- Exterior and openings: specify the finish, glazing and door or window arrangement.
- Interior and bathroom: confirm finish selections, sanitary fittings, furniture and accessories.
- Electrical services: state the destination standard, supply details, sockets, controls and equipment requirements.
Your choices can affect dimensions, weight, equipment and price. The approved quotation defines what is included.
Documentation
Product Documents
Share the documents required for your project and destination. We will confirm available records for the selected S5 configuration and components.
- Model information: Drawings and specifications matched to the selected S5 configuration.
- Component records: Certificates and test reports matched to the specified product, supplier and standard.
- Destination requirements: Documents required for the installation location, with project approval reviewed separately.
Whole-building and local project approval are separate from product and component documentation.
Transport and site coordination
Delivery & Site Preparation
Plan packing, transport, handling and site connections using the final unit size and weight.
- Unit accessories: lifting rings, transport fasteners, connectors and support legs are listed in the base accessory schedule.
- Transport: provide the destination, quantity and site-access information so the final shipping plan can be checked.
- Site services: coordinate the required power supply, water supply and drainage with the agreed equipment schedule.
- Handling: confirm lifting points, support conditions and unloading arrangements for the quoted unit.
Common Questions
S5 FAQs
Review the layout, included items and destination requirements before ordering.
What are the dimensions of S5?
The listed external dimensions are 7.5 × 3.3 × 3.2 m, with a nominal floor area of 24.7 m², occupancy for two to four people and an approximate total weight of 5 t.
Can the layout and finishes be changed?
Yes. Share your use, occupancy, preferred layout, finishes and equipment. The approved specification and quotation define the supplied configuration.
Can electrical components suit our country?
Destination-specific switches, sockets and wiring can be specified. Provide the project location, supply voltage, frequency and applicable requirements with the enquiry.
Are all items shown in the images included?
Images show layout and finish examples. Furniture, appliances, fittings and accessories are included only when specified in your quotation.
What does the 10 kW figure represent?
It is the electrical-power figure listed for the base configuration, not an energy-consumption guarantee. Confirm the final equipment schedule and site power requirements for the selected unit.
What information is needed for a quotation?
Send the quantity, destination, use, layout, finishes, electrical standard, equipment needs and target delivery date.
Project enquiry
Specify your S5 unit
Send the quantity, destination, use, layout, finishes, electrical standard, equipment needs and target delivery date.
Electrical Configuration Options
Switches, sockets and wiring can be configured for Australian, US, European or other destination-market requirements. Tell us your destination and required standards. Final specifications and included items follow the agreed quotation.
Discuss Your Configuration →