← Space Capsule House

S4 · 38.4 m² two-level accommodation

S4 Space Capsule House

A 38.4 m² two-level capsule configuration for two to four people, with a lower living and bathroom zone, spiral stair, upper sleeping area and insulated steel-frame enclosure.

01 / 03 S4 front exterior reference. Finishes and openings follow the agreed configuration.

S4 Space Capsule House

S4 accommodation

A two-level 38.4 m² layout

The S4 arranges a living area and bathroom on the lower level, with a spiral staircase leading to the upper sleeping area. The base schedule is intended for two to four people.

S4 space capsule house lower and upper floor plans with living, bathroom, stair and sleeping zones
S4 lower- and upper-level layout illustration. Furniture shown does not define the supply scope; confirm the final arrangement and included items in your quotation.

Living, bathroom and sleeping zones across two levels

The illustrated arrangement places the living zone and bathroom on the lower level. A spiral staircase connects to the upper sleeping area, allowing the compact external form to separate daytime and sleeping functions.

  • Occupancy: two to four people in the base schedule.
  • Enclosure: galvanised steel-frame construction, insulated exterior panels, Low-E insulating glazing and laminated-glass openable windows.
  • Guest facilities: bathroom fittings, two split-system air conditioners, lighting, curtains and room controls.

Dimensions and configuration can be customised to your requirements. Final specifications and included items are confirmed in the agreed proposal and quotation.

Base specifications

S4 dimensions and capacity

The dimensions and specifications below describe the base two-level configuration. Changes to layout, finishes and equipment may affect dimensions, weight and price.

ParameterBase configuration
ModelS4 Space Capsule House
Lower-level dimensions (L × W × H)5,550 × 4,050 × 2,550 mm (5.55 × 4.05 × 2.55 m)
Upper-level dimensions (L × W × H)5,550 × 2,900 × 2,550 mm (5.55 × 2.9 × 2.55 m)
Nominal floor area38.4 m²
Occupancy2–4 people
Electrical power10 kW
Approximate total weight8 t (8,000 kg)

The listed level dimensions are not clear internal dimensions. Confirm the final shipping dimensions, equipment load and unit weight for the agreed configuration before arranging transport or site connections.

Structure and envelope

Frame, glazing and exterior openings

A galvanised steel frame supports the insulated enclosure. Aluminium-alloy exterior panels, curtain-wall glazing and laminated-glass openable windows define the S4 base configuration.

ComponentBase configuration
Main frameGalvanised steel-frame structure
Exterior panelsAluminium-alloy panels
Exterior coatingFluorocarbon paint finish
InsulationPolyurethane insulation layer
Curtain-wall glazingLow-E tempered insulating glazing, 6 + 15A + 6 configuration
Openable windowsLaminated tempered glazing, 6 + 1.52 + 6 configuration
Entrance doorCustom entrance door
Entrance lockOutdoor waterproof smart door lock for hospitality use
Equipment compartmentCompartment for air-conditioning and water-heating equipment
Equipment-compartment doorCustom aluminium-alloy door
Perimeter lightingSurrounding ambient light strip
Top lightingSurrounding ambient light strip

Confirm required finishes, opening arrangements and project-specific structural requirements with your enquiry. Final materials and details follow the agreed specification.

Interior finishes

Two-level interior and spiral stair

Panel finishes, flooring, lighting, curtains and the internal spiral stair form the base interior package. Discuss your preferred finishes and room arrangement before confirming the order.

ComponentBase configuration
Bedroom ceilingAluminium-alloy ceiling panels
Internal staircaseSpiral staircase
Bedroom wall panelsCarbon-crystal decorative panels
Bedroom flooring6 mm SPC click-lock flooring
Bedroom ambient lightingSurrounding ambient light strips
Bedroom general lightingDownlights
Curtain trackMotorised curtain track
Bathroom ceilingBamboo-wood fibre panels
Bathroom wall panelsCarbon-crystal decorative panels
Bathroom flooringSlip-resistant ceramic tiles
Bathroom privacy doorOne-way frosted tempered-glass door

Bathroom equipment

Sanitary fittings and hot water

The base bathroom package includes sanitary fixtures, water heating, lighting and ventilation. Equipment specifications and included fittings are confirmed with the selected layout.

ComponentBase configuration
Hot-water equipment and showerElectric water heater and shower fittings
Vanity and basinCustom sintered-stone washbasin and vanity, mirror, cabinet and floor drain
ToiletToilet fixture
Lighting and ventilationBathroom lighting and ventilation
AccessoriesTowel rack

Confirm water-heater capacity, fixture selections and water-supply and drainage requirements in the agreed specification.

Electrical and services

Coordinate equipment with your destination

Switches, sockets and wiring can be configured to Australian, US, European or other destination-market requirements. Specify your destination, required electrical standards and power-supply details when enquiring.

ComponentBase configuration
Base wiring1.5 / 2.5 / 4 / 10 mm² electrical cables and Category 6 network cable; final cable specification follows destination and equipment requirements
Cable conduitInsulating PVC conduit
Water supply and drainagePressure-resistant water-supply and drainage pipework
Air conditioningTwo 1.5 HP-class split-system heating and cooling air conditioners in the base schedule
SocketsDestination-specific sockets; three-hole and five-hole formats are base examples, not the only choices
SwitchesSwitch panels configured for the required destination standard

The 1.5 HP class describes the base air-conditioner size, not an electrical-input or cooling-capacity value. Final component specifications and included items are confirmed in the agreed proposal and quotation.

Room controls

Lighting, curtains and guest-room power

The base room-control functions support guest-room lighting, curtains and power management. Confirm the selected control functions and equipment with your fit-out package.

FunctionBase configuration
Key-card power controlInsert card to enable power; remove card to disconnect power
Scene controlsMulti-scene function panel
Lighting controlsIntelligent lighting control
Curtain controlsIntelligent curtain control
Voice controlsIntelligent voice-control system

Configuration choices

Tailor the S4 to your project

The base configuration is a starting point for the enquiry. Tell us which dimensions, layout, finishes or equipment need to change.

  • Dimensions and layout: discuss required external dimensions, lower- and upper-level arrangement and intended occupancy.
  • Finishes and fit-out: specify exterior and interior finish preferences, bathroom fittings and room-control requirements.
  • Electrical components: request switches, sockets and wiring suited to your destination, including Australian, US or European requirements.
  • Included items: confirm furniture, appliances and accessories explicitly in the quotation. Items shown in a visualisation are not automatically included.

Customisation may affect dimensions, weight, equipment selection and price. Final specifications and included items follow the agreed proposal and quotation.

Documentation scope

Confirm model and component documents before order

The available document package contains a capsule-house verification document and separate certificates or test records for specified components. The verification document does not map every workbook model name, so its applicability to the quoted S4 must be confirmed.

  • Model scope: do not treat category-level documentation as blanket S4 certification or general regulatory approval.
  • Component scope: component documents apply only to the identified product, supplier and stated standard.
  • Destination check: identify the documents required for the destination and confirm which quoted components they cover.

Document availability does not replace project-specific approval, local code review or confirmation of final components.

Transport and site coordination

Plan delivery for the agreed unit

Use the final dimensions and weight to confirm packing, shipping and handling arrangements. Share your delivery destination and site conditions before ordering.

  • Unit accessories: lifting rings, transport fasteners, connectors and support legs are part of the base accessory package. Confirm included quantities and handling arrangements.
  • Transport: provide the destination, quantity and site-access information. Shipping dimensions and weight must match the selected configuration.
  • Site connections: coordinate the required power supply, water supply and drainage with the unit’s agreed equipment and connection details.
  • Documentation: identify any project-specific drawings or component documentation needed for your destination before confirming the order.

Procurement FAQs

Before ordering the S4

Clarify your configuration, supply scope and destination requirements to obtain a project-specific quotation.

Can the S4 dimensions and configuration be customised?

Yes. The base configuration uses lower-level dimensions of 5.55 × 4.05 × 2.55 m and upper-level dimensions of 5.55 × 2.9 × 2.55 m, with a nominal 38.4 m² floor area and occupancy for two to four people.

Share your required dimensions, layout and equipment. Final specifications and included items are confirmed in the agreed proposal and quotation.

Can switches, sockets and wiring suit our country?

Yes. Australian, US, European and other destination-specific configurations are available. Provide the destination, required electrical standards and power-supply details. The base cable sizes and socket formats are not the only choices.

Are the bed and all items in the illustration included?

Not automatically. The exterior and floor plans illustrate the S4 appearance and room arrangement. Furniture, appliances, fittings and accessories must be confirmed in your quotation.

What does the 10 kW specification mean?

It is the electrical-power figure for the base S4 configuration, not an energy-consumption guarantee. Confirm the final equipment schedule and site power-supply requirements for your selected package.

Does the available documentation approve the complete S4 building?

No blanket approval should be inferred. Confirm the document scope, selected components and destination requirements for the quoted unit before ordering.

What is needed to discuss transport and a quotation?

Send your destination, quantity, intended use, required dimensions, preferred layout and equipment, electrical requirements and target delivery date. Shipping and handling arrangements depend on the agreed unit dimensions and weight.

Project enquiry

Specify your S4 unit

Send the quantity, destination, intended use, preferred finishes, electrical standard and target delivery date. We will confirm the final component and commercial schedule in the quotation.

Request a project quote →